High quality human machine interface provider

Human machine interface manufacturer and supplier right now: Consider the typical problems in interface design: To design any interface, we must generally consider four aspects: system response time, user help mechanism, error message handling and command mode. System response time is too long is the most complained about in the interactive system, in addition to the absolute length of the response time, the user is concerned about the difference in response time of different commands, if too much disparity in the user will be difficult to accept; user help mechanism should be integrated, to avoid the superimposed system leads to the user to help a guide and have to browse a lot of irrelevant information; error and warning information must be selected user understandable The error and warning messages must be user-friendly, accurate terminology, and should also provide some suggestions for error recovery as much as possible. In addition, the display of error information, if supplemented by auditory (ringing), visual (special color) stimulation, it is more effective; command mode is best to menu and keyboard commands coexist for the user to choose. Discover more info on hmi panel.

System Reliability Requirements: The reliability of the general system PLC can be met. For systems with high reliability requirements, consider whether to use redundant systems or hot standby systems. PLC should be unified possible. Mainly consider the following three aspects: The model is unified, and its modules can be used as backup for each other, which is convenient for the procurement and management of spare parts. The model is unified and its function and use method are similar, which is conducive to the training of technical forces and the improvement of technical level. The model is unified, its external equipment is universal, resources can be shared, easy to network communication, and it is easy to form a multi-level distributed control system after being equipped with a computer.

Frequency principle: That is, according to the frequency of dialogue interaction of the management object design the human-machine interface hierarchical order and dialogue window display position of the list, etc., to improve the frequency of monitoring and access to dialogue. Importance principle: That is, in accordance with the importance of management objects in the control system and the global level, the design of the human-machine interface of the main and secondary menus and the location and prominence of the dialogue window, which helps managers to grasp the importance of the control system, the implementation of good control of the sequence of decisions to achieve optimal scheduling and management.

Less performance used to match a very high cost, so will it worth? And where is your market point? Maybe more consider another China brand with a very perfect performance too, such as Mochuan brand. Welcome contact us to discuss more. The Second Step: Selecting The HMI Screen Size There are two means of size here. One is screen display screen size, the other is CPU size. Integrating the scale of the entire project, to determine the size of the HMI panel needs, through the project as a whole to present the effect. Do not select the size is too small or too large, becuase too small is look very compact and not enough to operate in well, too large will look the overall proportion of the untuned and waste. It requires engineers to design a good enginnering diagram in advance to allocate the size of each accessory part of the proportion. Wanna win every high value market, it needs to pre-design and seriously selected, but not take for granted. Find additional info at mochuan-drives.com.

Why touch panel interface always fail to communicate with PLC? Common reasons why touchscreens do not communicate with PLCs 1. whether the correct communication protocol is selected (Modbus, Profibus, CANopen, etherCAT) 2. Is the communication line normal (RS232 rxd TXD GND RS485 a+B-CANopen CAN_L CAN_H CAN_GND ether cat network cable) 3. Whether the communication parameters are correct (station number, baud rate, parity bits) 4. Whether there is interference The program determines that the communication between HMI operator interface and plc has fialed

Multi-touch capacitive hmi panel is new design and very popular with the market. Why? It is similar the Apple iPone in our life. Becuase its flexible multi touch, very high transmittance, Glass+Glass, anti-scratching, no drifting, IPS full view TFT lcd, high resolution, brightness, high speed and easy flow, supporting animation formats. The color of multitouch HMI is rich and the picture displayed is more delicate. Why many people follows iPhone, just becuase it can bring the users different and beyond imagination experience. Same reasons, why this type panel hmi is very popular in European and American market, just becuase it can bring the project, equipment different experience then to obtain more high value market and to be easily competitive the competitors. Maybe a little try, but to bring a large value, so why not try.

There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.

The reason is rs232 is suitable for communication between local devices, and its transmission distance is generally not more than 15m, and rs232 only allows one-ton-one communication. But rs485 transmission distance is from tens of meters up to 2Km, and rs485 interface allows up to 255 slave station to be connected. These are required to be designed by our engineers, with whom to communicate, how many devices to communicate, how to achieve the final function, whether to take into consider the interference problems of the field environment etc. All of the above are considered.

Electrical cabinets are integrated cabinets used to accommodate electrical or various electrical equipment used as a carrier for electrical control equipment. It can provide strong protection against water, dust and electromagnetic interference to the stored objects. In the era of big data and the construction of intelligent industry, electrical cabinet control equipment is also playing a very important role. How can we better control the electrical equipment in the harsh environment of the electrical room? Here we recommend Mochuan drives industrial hmi touch panel for embedded installation.

Human-machine interfaces exist in all areas where human-machine information exchange is involved. A large number of industrial and commercial use, a simple distinction between “input” (Input) and “output” (Output) two, input refers to the operation of machinery or equipment by people, such as handles, switches, doors, instructions (orders) issued or maintenance, and output refers to the machinery or equipment issued by the notice, such as failure, warning, operating instructions tips, etc., a good human-machine interface will Help users more simple, more correct, more rapid operation of machinery, but also to maximize the performance of machinery and extend the service life, and the market refers to the human-machine interface is more narrowly defined in the software user-friendly operating interface.

Related posts